Traxbean Ankle Tracker Passed the EMC Test – 7
Ankle Tracker
Ankle tracker beacon is an excellent product we can enable the indoor tracking in the law enforcement solutions. To get more information please click the link Contact Us
Ankle Tracker Design
We design a tamper proof ankle tracker from PCBA, DFM(Design for manufacturability) key point is safe, Electromagnetic Compatibility is one of the requirements.
Social Media
Surges
Environmental conditions:
Temperature:15-35 ℃, Humidity:45-75 %RH
Reference documents:
IEC61000-4-2:2001 Testing and measurement techniques-Electrostatic discharge immunity test.
Test arrangement:
Sample state:
Sample is in good condition before test
Test conditions:
The test sample is in normal state
1kV Line to Line: Differential mode.
(Voltage Waveform: 1.2/50 us; Current Waveform: 8/20 us)
General performance criteria:
Performance criteria A for immunity tests with phenomena of a continuous nature;
Performance criteria B for immunity tests with phenomena of a transient nature;
Performance criteria C for immunity tests with power interruptions exceeding a certain time.
Test acceptance requirements:
Criteria B.
Test Result:
Criteria B.
Test conclusion:
Passed
Test Photo
The ankle tracker is used for prisoner/offender/criminal tracking in the community correction program.